Lantick PE-4-4

664.20 zł

Lantick 4-4 is an advanced input/output control module designed for monitoring and managing four inputs and four relay outputs. Its sturdy construction ensures device reliability and durability. The user-friendly interface simplifies device configuration and control.

With support for various communication protocols such as HTTP, Modbus TCP, SNMP, TCP, UDP, KNX/IP, the module seamlessly integrates with different building management systems, alarm systems, and monitoring systems. Additionally, the built-in web server enables remote management and configuration of the device through a web browser.

Power options include Passive PoE 10-24VDC and DC: 12-24VDC.

Quantity
Available

Lantick PE-4-4 - go to the product website

Technical data

Power supply

  • Passive PoE 10V – 24V DC
  • DC: 10 V - 24V
  • Power consumption: max 4.2W

Ports

  • LAN – Ethernet 1x10Mbps, RJ45
  • RS485 - optional

Communication protocols

  • Modbus TCP
  • KNX/IP
  • HTTP GET
  • TCP
  • UDP
  • SNMP
  • Inveo Dashboard service
  • Embedded web server
  • Control from the Windows command line
  • Control from the Linux console

Inputs

  • Number of inputs: 4
  • Input type: transoptor
  • Input voltage: 10-24V
  • Maximum counter value: 4 294 967 296
  • Maximum input frequency: 1000Hz

Outputs

  • Number of outputs: 4
  • Output type: relay, NO
  • Maximum working voltage: 250 VAC
  • Maximum load current per channel: 2A
  • Switching on time: 1ms
  • Switching off time: 5ms
  • Operating modes: bistable, astable, monostable (single release), shutter (roller shutter control)
  • Switch on / off time resolution: 100ms
  • Socket: screw connectors

Housing

  • Dimensions: 104.8 x 90 x 65 mm
  • Ingress protection: IP30
  • Mounted on a DIN rail

LEDs

  • Power – power supply
  • Link – LAN connected
  • Act – active LAN connection
  • Outputs 1-4 – active relay outputs 1- 4
  • Inputs 5-8 – active inputs 5-8
  • Safe – loss of Modbus RTU communication (option)
  • Remote – connection 1 to 1 or to the Dashboard server
  • DHCP – active DHCP mode
  • Norm – module in standard operation mode
  • Boot – module in Bootloader mode

Additionally

  • Visualization of input and output states on own graphics
  • Work in M2M mode
  • Input simulation mode
  • Password protection for the administrator and user

Data sheet

Power
Passive PoE 12-24VDC
Screw connector 12-24VDC
Number of outputs
4
Output type
Relay
Number of inputs
4
Input type
Voltage (10-24V)
Communication
LAN
Communication protocols
HTTP GET
KNX/IP
Modbus TCP
SNMP v2c
TCP
command line program
device with Android system
Housing
DIN rail

You might also like